Skip to content

HVBATT_a278 — Acjb Cp Line Relay May Be Welded

Full alert identifier: HVBATT_a278_AcjbCpLineRelayMayBeWelded

Alert description

The battery management system (BMS) has detected that the AC Junction Box (ACJB) Charge Port (CP) line relay may be welded.

Potential impact

Outlets unavailable. DC charging unavailable.

Set condition

The ACJB charge port line relay may be welded

Clear condition

The BMS no longer qualifies the relay as welded.

Signals to check

These diagnostic fields are associated with HVBATT_a278. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Min Voltage To Disqualify Weld HVBATT_a278_minVoltageToDisqualifyWeld
4095
SNA
V
Voltage Across Contacts HVBATT_a278_voltageAcrossContacts
4095
SNA
V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a278.

Browse all HVBATT alert codes