Skip to content

HVBATT_a263 — Acjb Bed L3 Relay Welded

Full alert identifier: HVBATT_a263_AcjbBedL3RelayWelded

Alert description

The battery management system (BMS) has detected that the AC Junction Box (ACJB) bed outlet line 3 relay has welded.

Potential impact

AC charging unavailable.

Set condition

A welded ACJB bed outlet line 3 relay is detected

Clear condition

The BMS no longer qualifies the relay as welded.

Signals to check

These diagnostic fields are associated with HVBATT_a263. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Min Voltage To Disqualify Weld HVBATT_a263_minVoltageToDisqualifyWeld
4095
SNA
V
Voltage Across Contacts HVBATT_a263_voltageAcrossContacts
4095
SNA
V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a263.

Browse all HVBATT alert codes