HVBATT_a056 — Brick Voltage Mia

Full alert identifier: HVBATT_a056_BrickVoltageMia

Alert description

Indicates valid data is missing for one or more brick voltages

Potential impact

Brick voltage data is likely being substituted to replace invalid readings

Set condition

One or more brick voltages are continuously detected as invalid

Clear condition

All brick voltages continuously have valid data

Signals to check

These diagnostic fields are associated with HVBATT_a056. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Num Bad Readings HVBATT_a056_numBadReadings —
Num Sna Readings HVBATT_a056_numSnaReadings —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a056.

Browse all HVBATT alert codes