GTW_w300 — Mcu Undervoltage Protection Self Test
Full alert identifier: GTW_w300_mcuUndervoltageProtectionSelfTest
Alert description
The vehicle Gateway (GTW) detects the undervoltage protection self-test on the Media Control Unit (MCU) did not pass successfully. Driving is disabled as the low voltage (LV) systems may not be protected from an undervoltage event.
Potential impact
Vehicle is unable to drive until the MCU provides undervoltage protection to the LV systems.
Set condition
The vehicle GTW detects the undervoltage protection self-test on the MCU did not pass successfully.
Clear condition
The vehicle GTW detects the undervoltage protection self-test on the MCU passes successfully, indicating the MCU is now able to provide undervoltage protection to the LV systems.
Signals to check
These diagnostic fields are associated with GTW_w300. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Mcu Undervoltage Protection Self Test
GTW_
|
— |
Mcu Uv Prot Self Test Fail Reason
GTW_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of GTW_w300.