GTW_w277 — Non Rev C DrMOS Mitigation Failed
Full alert identifier: GTW_w277_NonRevCDrMOSMitigationFailed
Alert description
The Gateway (GTW) attempted to apply a mitigation for non Rev-C Driver and MOSFET (DrMOS) component by programming the power management controller, but the mitigation attempt was unsuccessful. If the mitigation is unsuccessful, the media control unit (MCU) may be unable to start due to the false detection of over current conditions.
Potential impact
The center display may be blank due to the false detection of an over current condition, preventing the MCU from waking.
Set condition
The mitigation attempt was unsuccessful.
Clear condition
The mitigation attempt was successful.
Signals to check
These diagnostic fields are associated with GTW_w277. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Mitigation Failure Reason
GTW_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of GTW_w277.