FC_a282 — GB neg Temp Hi Fold Bk

Full alert identifier: FC_a282_GB_negTempHiFoldBk

Alert description

The GB (China) DC fast charge (FC) rate is reduced because the FC electronic control unit (ECU) detects that the adapter negative pin temperature is higher than the expected value.

Potential impact

Maximum DC charging rate is reduced.

Set condition

The FC ECU detects that the negative pin temperature is above the alert threshold.

Clear condition

The FC ECU detects that the negative pin temperature is within expected bounds.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of FC_a282.