FC_a130 — CA flyback SW OV

Full alert identifier: FC_a130_CA_flyback_SW_OV

Alert description

The vehicle is unable to begin CHAdeMO DC fast charging because the fast charge (FC) electronic control unit (ECU) detects a software overvoltage event during flyback.

Potential impact

DC fast charging is unavailable.

Set condition

The FC ECU detects that the flyback voltage is over the alert threshold.

Clear condition

The FC ECU detects that the flyback voltage is within expected bounds.

Signals to check

These diagnostic fields are associated with FC_a130. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
CA Flyback Sw Ov Type FC_a130_CA_flybackSwOvType —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of FC_a130.

Browse all FC alert codes