ESP_a039 — Fr RWSS Open Or Short To Gnd

Full alert identifier: ESP_a039_FrRWSSOpenOrShortToGnd

Alert description

Short circuit of the WSS_FR sensor line to GND or line interruption (sensor or supply line).

Potential impact

Will disable VDC/TC and degrade ABS

Set condition

Short circuit of the sensor line to GND or line interruption (sensor- or supply line) .

Clear condition

Check WSS connection for short circuit and repair/replace harness or sensor

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of ESP_a039.

Browse all ESP alert codes