Skip to content

EGGRIGHT_a054 — Amplifier Faults

Full alert identifier: EGGRIGHT_a054_amplifierFaults

Alert description

The Ethernet Generalized Gateway (EGGxxx) detects a condition affecting the health of the amplifier.

Potential impact

Audio quality may decrease.

Set condition

An amplifier condition is reported. Alert log signal data should provide more information on the specific condition(s) detected.

Clear condition

An amplifier condition is no longer reported.

Signals to check

These diagnostic fields are associated with EGGRIGHT_a054. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Channel Dc Fault Ch 1 EGGRIGHT_a054_channelDcFaultCh1 —
Channel Dc Fault Ch 2 EGGRIGHT_a054_channelDcFaultCh2 —
Channel Dc Fault Ch 3 EGGRIGHT_a054_channelDcFaultCh3 —
Channel Dc Fault Ch 4 EGGRIGHT_a054_channelDcFaultCh4 —
Channel Over Current Ch 1 EGGRIGHT_a054_channelOverCurrentCh1 —
Channel Over Current Ch 2 EGGRIGHT_a054_channelOverCurrentCh2 —
Channel Over Current Ch 3 EGGRIGHT_a054_channelOverCurrentCh3 —
Channel Over Current Ch 4 EGGRIGHT_a054_channelOverCurrentCh4 —
Show 14 more fields
Signal Unit
Clock Error EGGRIGHT_a054_clockError —
Over Temperature Shutdown Ch 1 EGGRIGHT_a054_overTemperatureShutdownCh1 —
Over Temperature Shutdown Ch 2 EGGRIGHT_a054_overTemperatureShutdownCh2 —
Over Temperature Shutdown Ch 3 EGGRIGHT_a054_overTemperatureShutdownCh3 —
Over Temperature Shutdown Ch 4 EGGRIGHT_a054_overTemperatureShutdownCh4 —
Over Temperature Shutdown Global EGGRIGHT_a054_overTemperatureShutdownGlobal —
Over Temperature Warning Ch 1 EGGRIGHT_a054_overTemperatureWarningCh1 —
Over Temperature Warning Ch 2 EGGRIGHT_a054_overTemperatureWarningCh2 —
Over Temperature Warning Ch 3 EGGRIGHT_a054_overTemperatureWarningCh3 —
Over Temperature Warning Ch 4 EGGRIGHT_a054_overTemperatureWarningCh4 —
Over Temperature Warning Global EGGRIGHT_a054_overTemperatureWarningGlobal —
Pvdd Error EGGRIGHT_a054_pvddError
0
NO ERROR
1
UNDERVOLTAGE
2
OVERVOLTAGE
—
Vbat Error EGGRIGHT_a054_vbatError
0
NO ERROR
1
UNDERVOLTAGE
2
OVERVOLTAGE
—
Vdd Power On Reset EGGRIGHT_a054_vddPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT_a054.

Browse all EGGRIGHT alert codes