Skip to content

EGGRIGHT_a052 — Etherloop Error

Full alert identifier: EGGRIGHT_a052_EtherloopError

Alert description

A condition affecting Etherloop communication has been detected, such as a link down, electronic control unit (ECU) / switch down, or power domain issue.

Potential impact

Loss of communication redundancy or total loss of communication between some electronic control units (ECUs).

Set condition

Etherloop Generalized Gateway (EGG) has detected a condition affecting Etherloop communication.

Clear condition

Condition affecting Etherloop communication is no longer detected.

Signals to check

These diagnostic fields are associated with EGGRIGHT_a052. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
App CCW EGGRIGHT_a052_appCCW —
App CW EGGRIGHT_a052_appCW —
App Ecu EGGRIGHT_a052_appEcu —
Eggleft CCW EGGRIGHT_a052_eggleftCCW —
Eggleft CW EGGRIGHT_a052_eggleftCW —
Eggleft Ecu EGGRIGHT_a052_eggleftEcu —
Eggrear CCW EGGRIGHT_a052_eggrearCCW —
Eggrear CW EGGRIGHT_a052_eggrearCW —
Show 10 more fields
Signal Unit
Eggrear Ecu EGGRIGHT_a052_eggrearEcu —
Eggright CCW EGGRIGHT_a052_eggrightCCW —
Eggright CW EGGRIGHT_a052_eggrightCW —
Eggright Ecu EGGRIGHT_a052_eggrightEcu —
Error EGGRIGHT_a052_error —
Gtw CCW EGGRIGHT_a052_gtwCCW —
Gtw CW EGGRIGHT_a052_gtwCW —
Gtw Ecu EGGRIGHT_a052_gtwEcu —
Left Power Domain EGGRIGHT_a052_leftPowerDomain —
Right Power Domain EGGRIGHT_a052_rightPowerDomain —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT_a052.

Browse all EGGRIGHT alert codes