EGGLEFTVC_a448 — Steering Col Up Down Endstop Cal

Full alert identifier: EGGLEFTVC_a448_steeringColUpDownEndstopCal

Alert description

Steering column up / down motor end stop is not within the expected range.

Potential impact

Calibration may have been unsuccessful. Steering column profile recall may not operate as expected.

Set condition

The full range of up / down movement is less than 53mm or greater than 64mm.

Clear condition

New calibration attempt has started.

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a448. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Endstop Position MM EGGLEFTVC_a448_endstopPositionMM mm
Motor Type EGGLEFTVC_a448_motorType
2
BOSCH COMMON TO JE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a448.