Skip to content

EGGLEFTVC_a414 — Undervoltage Self Test Failure

Full alert identifier: EGGLEFTVC_a414_undervoltageSelfTestFailure

Alert description

The Left Domain Undervoltage self-test did not pass, as a condition affecting a load on the Left Domain was detected during the self-test.

Potential impact

The undervoltage protection circuit may not be functional.

Set condition

The Left Domain Undervoltage self-test does not succeed.

Clear condition

Vehicle controller reset or successful Left Domain Undervoltage self-test.

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a414. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Failure Reason EGGLEFTVC_a414_failureReason
0
NONE
1
DEVICE STUCK ON
2
BRIDGE
3
BRIDGE AND DEVICE STUCK ON
4
LOAD UNATTEMPTED ON
8
FOLLOWER
16
TIMEOUT
—
Load Unattempted On Failure EGGLEFTVC_a414_loadUnattemptedOnFailure —

Check other alerts