EGGLEFTVC_a389 — Steer Col In Out Encoder Out Of Range

Full alert identifier: EGGLEFTVC_a389_steerColInOutEncoderOutOfRange

Alert description

Steering column in/out encoder out of range

Potential impact

Steering column in/out position may be incorrect

Set condition

Steering column in/out encoder drifts out of the calibrated end stop

Clear condition

Run UDS routine to calibrate the steering column

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a389. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Current Position MM EGGLEFTVC_a389_currentPositionMM mm
Motor Current EGGLEFTVC_a389_motorCurrent A
Motor Type EGGLEFTVC_a389_motorType
2
BOSCH COMMON TO JE
—
Saved Endstop Position MM EGGLEFTVC_a389_savedEndstopPositionMM mm