EGGLEFTVC_a246 — Seat Enc Over Back
Full alert identifier: EGGLEFTVC_a246_seatEncOverBack
Alert description
The seat motor has traveled beyond the expected range.
Potential impact
Seat may be in an unstable position or a mechanism may not be functioning as expected.
Set condition
Seat position goes outside the acceptable range.
Clear condition
The seat motor has returned to the expected range.
Signals to check
These diagnostic fields are associated with EGGLEFTVC_a246. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Seat Motor Calibrated
EGGLEFTVC_
|
— |
Seat Motor Current
EGGLEFTVC_
|
A |
Seat Motor Pos Real
EGGLEFTVC_
|
mm |
Seat Motor State
EGGLEFTVC_
|
— |
Seat Switch Back
EGGLEFTVC_
|
— |
Seat Switch Forward
EGGLEFTVC_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a246.