Skip to content

EGGLEFTVC_a137 — TAS damper Valve Comp FL

Full alert identifier: EGGLEFTVC_a137_TAS_damperValveCompFL

Alert description

The front left compression damper valve experienced a condition affecting its operation.

Potential impact

No dampers will be powered.

Set condition

Front left compression damper valve detected to be unplugged, shorted, pin-swapped, or it experienced an internal condition.

Clear condition

Vehicle power state cycles from OFF to ON.

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a137. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Damper Valve Fault EGGLEFTVC_a137_damperValveFault —
Device On State Diagnostics EGGLEFTVC_a137_deviceOnStateDiagnostics —
Drv Device Fault EGGLEFTVC_a137_drvDeviceFault —
Drv Device Over Current EGGLEFTVC_a137_drvDeviceOverCurrent —
Drv Device Over Temperature EGGLEFTVC_a137_drvDeviceOverTemperature —
Drv Device Over Voltage EGGLEFTVC_a137_drvDeviceOverVoltage —
Drv Device Spi Comm Error EGGLEFTVC_a137_drvDeviceSpiCommError —
Drv Device Under Voltage EGGLEFTVC_a137_drvDeviceUnderVoltage —
Show 6 more fields
Signal Unit
Drv Failed Communication EGGLEFTVC_a137_drvFailedCommunication —
Drv Output Gnd Short EGGLEFTVC_a137_drvOutputGndShort —
Drv Output Open Circuit EGGLEFTVC_a137_drvOutputOpenCircuit —
Drv Output Over Current EGGLEFTVC_a137_drvOutputOverCurrent —
Drv Output Vm Short EGGLEFTVC_a137_drvOutputVmShort —
Drv Power On Reset EGGLEFTVC_a137_drvPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a137.

Browse all EGGLEFTVC alert codes