EGGLEFTVC_a137 — TAS damper Valve Comp FL
Full alert identifier: EGGLEFTVC_a137_TAS_damperValveCompFL
Alert description
The front left compression damper valve experienced a condition affecting its operation.
Potential impact
No dampers will be powered.
Set condition
Front left compression damper valve detected to be unplugged, shorted, pin-swapped, or it experienced an internal condition.
Clear condition
Vehicle power state cycles from OFF to ON.
Signals to check
These diagnostic fields are associated with EGGLEFTVC_a137. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Damper Valve Fault
EGGLEFTVC_
|
— |
Device On State Diagnostics
EGGLEFTVC_
|
— |
Drv Device Fault
EGGLEFTVC_
|
— |
Drv Device Over Current
EGGLEFTVC_
|
— |
Drv Device Over Temperature
EGGLEFTVC_
|
— |
Drv Device Over Voltage
EGGLEFTVC_
|
— |
Drv Device Spi Comm Error
EGGLEFTVC_
|
— |
Drv Device Under Voltage
EGGLEFTVC_
|
— |
Show 6 more fields
| Signal | Unit |
|---|---|
Drv Failed Communication
EGGLEFTVC_
|
— |
Drv Output Gnd Short
EGGLEFTVC_
|
— |
Drv Output Open Circuit
EGGLEFTVC_
|
— |
Drv Output Over Current
EGGLEFTVC_
|
— |
Drv Output Vm Short
EGGLEFTVC_
|
— |
Drv Power On Reset
EGGLEFTVC_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a137.