Skip to content

DI_a226 — Sys Start Condition Not Met

Full alert identifier: DI_a226_sysStartConditionNotMet

Alert description

The drive interface (DI) electronic control unit (ECU) detects that not all system start conditions are met.

Potential impact

Shift out of Park is blocked.

Set condition

The DI ECU detects that HV is not ready for at least 5 seconds in Drive, or there is an unconfirmed UI alert such as front trunk (frunk) opened, Falcon door opened (Model X only), or unknown proximity state for 10 seconds in Drive.

Clear condition

Clear when the high voltage (HV) system is ready, frunk closed (or user override UI alert), falcon doors closed (or user override UI alert), and proximity is not unknown (or user override UI alert).

Signals to check

These diagnostic fields are associated with DI_a226. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Falcon Door Open DI_a226_falconDoorOpen —
Frunk Not Latched DI_a226_frunkNotLatched —
Hv State Not Up For Drive DI_a226_hvStateNotUpForDrive —
Lv Status Not Ready DI_a226_lvStatusNotReady —
Prox Detected DI_a226_proxDetected —
Syst State DI_a226_systState —
Trunk Open DI_a226_trunkOpen —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DI_a226.