Skip to content

DIR_a123 — Loss Motor Control

Full alert identifier: DIR_a123_lossMotorControl

Alert description

Drive Inverter Warning: Loss of motor control

Potential impact

Unable to produce torque/power from drive unit

Set condition

Motors are not responding to DI commands

Clear condition

Motors respond to DI commands

Signals to check

These diagnostic fields are associated with DIR_a123. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bad Current DIR_a123_badCurrent A
Bad Flux DIR_a123_badFlux Wb
Bus Voltage DIR_a123_busVoltage V
Loss Reason DIR_a123_lossReason
1
NO FLUX UP
2
HIGH VAR FLUX
3
HIGH VAR CURR
4
HIGH FLUX DISTURBANCE
—
Loss Request DIR_a123_lossRequest kW
Motor RPM DIR_a123_motorRPM RPM
Variance D DIR_a123_varianceD A
Variance Q DIR_a123_varianceQ A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a123.

Browse all DIR alert codes