DIR_a060 — Heatsink UT

Full alert identifier: DIR_a060_heatsinkUT

Alert description

Drive Inverter Warning: Heatsink under temperature

Potential impact

No direct impact. Could damage drive inverter if temperature is continuously too low.

Set condition

Heatsink temperature (refer to heatsinkTemp) drops below lower temperature threshold

Clear condition

Heatsink temperature rises above lower temperature threshold

Signals to check

These diagnostic fields are associated with DIR_a060. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Heatsink Temp DIR_a060_heatsinkTemp C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a060.

Browse all DIR alert codes