DIR_a035 — Phase Current Balance
Full alert identifier: DIR_a035_phaseCurrentBalance
Alert description
Drive Inverter Warning: Phase current imbalance
Potential impact
Drive unit enters unit limp mode (see DI_a126_limpMode)
Set condition
Imbalanced phase currents detected. See payload signals for reason of trigger
Clear condition
Reason of trigger is no longer present
Signals to check
These diagnostic fields are associated with DIR_a035. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Frequency
DIR_
|
Hz |
No Drive Current
DIR_
|
— |
Phase Aerror
DIR_
|
— |
Phase Berror
DIR_
|
— |
Phase Cerror
DIR_
|
— |
Phase Current
DIR_
|
A |
Phase Difference
DIR_
|
% |
Reporting Phase
DIR_
|
— |
Show 3 more fields
| Signal | Unit |
|---|---|
Standby Current
DIR_
|
— |
Unbalanced Current
DIR_
|
— |
Wont Move Current
DIR_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a035.