Skip to content

DIR_a034 — Phase Bcurrent Sensor

Full alert identifier: DIR_a034_phaseBcurrentSensor

Alert description

The Drive Inverter (DIx) Phase B current sensor is irrational.

Potential impact

If the alert asserts at the beginning of a drive cycle, DIx may not enable. If the alert asserts during a drive cycle, DIx may be disabled. DIx may not function as expected.

Set condition

The DIx Phase B current sensor is irrational. An irrational current may indicate a high rate of change or current measurement out of sensing bounds. There may be a condition affecting current input and output.

Clear condition

The DIx Phase B current sensor is no longer irrational.

Signals to check

These diagnostic fields are associated with DIR_a034. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Delta Ib DIR_a034_deltaIb A
Phase Bcurrent DIR_a034_phaseBcurrent A
V Ref Ib DIR_a034_vRefIb V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a034.

Browse all DIR alert codes