DIR_a007 — Stator Anomaly Detected
Full alert identifier: DIR_a007_statorAnomalyDetected
Alert description
Drive Inverter Warning: Motor stator anomaly detected
Potential impact
Drive unit may fault
Set condition
Stator anomaly observed during retry attempt
Clear condition
Alert clears after retry attempt
Signals to check
These diagnostic fields are associated with DIR_a007. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Id Fdb Std Deviation
DIR_
|
A |
Iq Fdb Std Deviation
DIR_
|
A |
Motor Shift
DIR_
|
— |
Motor Short
DIR_
|
— |
Offset Error
DIR_
|
rad |
Phase Acurrent
DIR_
|
A |
Phase Bcurrent
DIR_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a007.