DIRER_a154 — Resolver
Full alert identifier: DIRER_a154_resolver
Alert description
The Drive Unit resolver (motor speed sensor) is not operating as expected. The resolver may have a condition affecting functionality.
Potential impact
The resolver is not operating as expected. The DIx invertor control board may be unable to correctly detect the angle and speed of the rotor.
Set condition
The Drive Unit resolver is not operating as expected. The resolver may have a condition affecting functionality.
Clear condition
The resolver begins functioning as expected. Review the logs to crack alert.
Signals to check
These diagnostic fields are associated with DIRER_a154. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Carrier Offset
DIRER_
|
— |
Cla MIA
DIRER_
|
— |
Common Gain
DIRER_
|
1 |
Error Table Invalid
DIRER_
|
— |
Motor RPM
DIRER_
|
RPM |
No Calibration
DIRER_
|
— |
No Carrier
DIRER_
|
— |
No Phase Lock
DIRER_
|
— |
Show 3 more fields
| Signal | Unit |
|---|---|
Not Ready
DIRER_
|
— |
Phase Error
DIRER_
|
1 |
Tracker Irrational
DIRER_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a154.