DIRER_a150 — Bus VD

Full alert identifier: DIRER_a150_busVD

Alert description

The High Voltage (HV) bus has measured a voltage drop in the HV battery pack. The Drive Inverter (DIx) may not operate as expected.

Potential impact

DIx may not operate as expected. Drive torque may be restricted.

Set condition

The HV bus has measured a voltage drop in the HV battery pack. DIx may not operate as expected.

Clear condition

The HV bus measures normal voltage in the HV battery pack.

Signals to check

These diagnostic fields are associated with DIRER_a150. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Elapsed Ms DIRER_a150_elapsedMs ms
Energy DIRER_a150_energy J
V Bat Filtered Rate DIRER_a150_vBatFilteredRate V/s
V Bat Raw Minus Filtered DIRER_a150_vBatRawMinusFiltered V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a150.