Skip to content

DIRER_a149 — Oil Pump Failure

Full alert identifier: DIRER_a149_oilPumpFailure

Alert description

Drive Inverter Warning: Oil pump failure

Potential impact

Initiates reduced drive unit performance and a speed limit on the vehicle, due to reduced gear lubrication and motor cooling

Set condition

Loss of communication or power to oil pump, persistent oil pump motor stall occurred, or persistent condition affecting oil pump functionality detected

Clear condition

Clears at the start of a drive cycle, if set condition is not present anymore

Signals to check

These diagnostic fields are associated with DIRER_a149. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Flow DIRER_a149_flow
255
SNA
LPM
Fluid Temp SNA DIRER_a149_fluidTempSNA —
Insufficient Flow DIRER_a149_insufficientFlow —
Motor Flow SNA DIRER_a149_motorFlowSNA —
Motor Open Phase DIRER_a149_motorOpenPhase —
Motor Shorted DIRER_a149_motorShorted —
Pcba ID DIRER_a149_pcbaID
0
LESS THAN 5
1
5
—
Response Error DIRER_a149_responseError —
Show 3 more fields
Signal Unit
State DIRER_a149_state
0
STANDBY
1
ENABLE
2
COLD STARTUP
6
FAULTED
7
SNA
—
Temperature DIRER_a149_temperature DegC
Voltage DIRER_a149_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a149.

Browse all DIRER alert codes