Skip to content

DIRER_a123 — Loss Motor Control

Full alert identifier: DIRER_a123_lossMotorControl

Alert description

Drive Inverter Warning: Loss of motor control

Potential impact

Unable to produce torque/power from drive unit

Set condition

Motors are not responding to DI commands

Clear condition

Motors respond to DI commands

Signals to check

These diagnostic fields are associated with DIRER_a123. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bad Current DIRER_a123_badCurrent A
Bad Flux DIRER_a123_badFlux Wb
Bus Voltage DIRER_a123_busVoltage V
Loss Reason DIRER_a123_lossReason
1
NO FLUX UP
2
HIGH VAR FLUX
3
HIGH VAR CURR
4
HIGH FLUX DISTURBANCE
—
Loss Request DIRER_a123_lossRequest kW
Motor RPM DIRER_a123_motorRPM RPM
Variance D DIRER_a123_varianceD A
Variance Q DIRER_a123_varianceQ A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a123.

Browse all DIRER alert codes