Skip to content

DIF_a160 — Bus Voltage Anomaly

Full alert identifier: DIF_a160_busVoltageAnomaly

Alert description

The High Voltage (HV) bus has detected a voltage anomaly in the HV battery pack. The Drive Inverter (DIx) may not operate as expected.

Potential impact

DIx may not operate as expected. Drive torque may be restricted.

Set condition

The HV bus has measured a voltage anomaly in the HV battery pack. DIx may not operate as expected.

Clear condition

The HV bus measures normal voltage in the HV battery pack.

Signals to check

These diagnostic fields are associated with DIF_a160. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Elapsed Ms DIF_a160_elapsedMs ms
Energy DIF_a160_energy J
V Bat Filtered Rate DIF_a160_vBatFilteredRate V/s
V Bat Raw Minus Filtered DIF_a160_vBatRawMinusFiltered V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIF_a160.

Browse all DIF alert codes