DIF_a047 — Stator Sensor1
Full alert identifier: DIF_a047_statorSensor1
Alert description
Drive Inverter Warning: Stator sensor 1 bad
Potential impact
Stator sensor 2 will be used instead (if available)
Set condition
Abnormal temperature measurements from stator sensor 1
Clear condition
Stator sensor 1 returns to rational temperature measurements
Signals to check
These diagnostic fields are associated with DIF_a047. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Stator Temp 1
DIF_
|
DegC |
Stator Tslope 1
DIF_
|
DegC/s |