Skip to content

DIF_a047 — Stator Sensor1

Full alert identifier: DIF_a047_statorSensor1

Alert description

Drive Inverter Warning: Stator sensor 1 bad

Potential impact

Stator sensor 2 will be used instead (if available)

Set condition

Abnormal temperature measurements from stator sensor 1

Clear condition

Stator sensor 1 returns to rational temperature measurements

Signals to check

These diagnostic fields are associated with DIF_a047. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Stator Temp 1 DIF_a047_statorTemp1 DegC
Stator Tslope 1 DIF_a047_statorTslope1 DegC/s

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIF_a047.

Browse all DIF alert codes