DIF_a024 — Self Test
Full alert identifier: DIF_a024_selfTest
Alert description
The Switch Off Path Test (SOPT) for Drive Unit has failed. The pathway between Drive Inverter (DIx) and Pedal Monitor (PM) torque measurements are different.
Potential impact
PM may not be able to shut down torque produced by Drive Unit.
Set condition
The Switch Off Path Test (SOPT) for Drive Unit has failed. The DIx and PM torque measurements are different. The pathway between DIx and PM may have a condition affecting functionality.
Clear condition
This alert is primarily intended for logging purposes. If this alerts repeatedly asserts, there may a condition affecting the DIx hardware.
Signals to check
These diagnostic fields are associated with DIF_a024. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ia
DIF_
|
A |
Ib
DIF_
|
A |
Fail Reason
DIF_
|
— |
Max Curr Mag Sqrd
DIF_
|
A2 |
Rotor Angle
DIF_
|
degrees |
State
DIF_
|
— |
V Bat
DIF_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIF_a024.