Skip to content

DIF_a003 — Hw Phase Cgate Drive

Full alert identifier: DIF_a003_hwPhaseCgateDrive

Alert description

The Drive Inverter (DIx) has detected a condition affecting functionality at the gate driver on Phase C.

Potential impact

DIx may be inoperable.

Set condition

DIx has detected a condition affecting functionality at the gate driver on Phase C. View payload signal to confirm reason for alert.

Clear condition

DIx no longer detects a condition affecting functionality at the gate driver on Phase C.

Signals to check

These diagnostic fields are associated with DIF_a003. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Asynch Stop H DIF_a003_asynchStop_H —
Asynch Stop L DIF_a003_asynchStop_L —
Deadtime Error H DIF_a003_deadtimeError_H —
Deadtime Error L DIF_a003_deadtimeError_L —
Desat H DIF_a003_desat_H —
Desat L DIF_a003_desat_L —
Fault Line 1 Gpio H DIF_a003_faultLine1Gpio_H —
Fault Line 1 Gpio L DIF_a003_faultLine1Gpio_L —
Show 37 more fields
Signal Unit
Gate Drive Err Counter DIF_a003_gateDriveErrCounter —
Local Comm Error H DIF_a003_localCommError_H —
Local Comm Error L DIF_a003_localCommError_L —
Local Reg Error H DIF_a003_localRegError_H —
Local Reg Error L DIF_a003_localRegError_L —
Local Reset H DIF_a003_localReset_H —
Local Reset L DIF_a003_localReset_L —
Overvolt VDD H DIF_a003_overvoltVDD_H —
Overvolt VDD L DIF_a003_overvoltVDD_L —
Overvolt VH H DIF_a003_overvoltVH_H —
Overvolt VH L DIF_a003_overvoltVH_L —
Overvolt VL H DIF_a003_overvoltVL_H —
Overvolt VL L DIF_a003_overvoltVL_L —
Remote Comm Error H DIF_a003_remoteCommError_H —
Remote Comm Error L DIF_a003_remoteCommError_L —
Remote Reg Error H DIF_a003_remoteRegError_H —
Remote Reg Error L DIF_a003_remoteRegError_L —
Remote Reset H DIF_a003_remoteReset_H —
Remote Reset L DIF_a003_remoteReset_L —
Selftest Desat H DIF_a003_selftestDesat_H —
Selftest Desat L DIF_a003_selftestDesat_L —
Sense H DIF_a003_sense_H —
Sense L DIF_a003_sense_L —
Spi Error H DIF_a003_spiError_H —
Spi Error L DIF_a003_spiError_L —
Thermal Shutdown H DIF_a003_thermalShutdown_H —
Thermal Shutdown L DIF_a003_thermalShutdown_L —
Thermal Warning H DIF_a003_thermalWarning_H —
Thermal Warning L DIF_a003_thermalWarning_L —
Undervolt VCC H DIF_a003_undervoltVCC_H —
Undervolt VCC L DIF_a003_undervoltVCC_L —
Undervolt VDD H DIF_a003_undervoltVDD_H —
Undervolt VDD L DIF_a003_undervoltVDD_L —
Undervolt VH H DIF_a003_undervoltVH_H —
Undervolt VH L DIF_a003_undervoltVH_L —
Undervolt VL H DIF_a003_undervoltVL_H —
Undervolt VL L DIF_a003_undervoltVL_L —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIF_a003.