Skip to content

DFLKR_a018 — Coil Overcurrent

Full alert identifier: DFLKR_a018_coilOvercurrent

Alert description

Differential Locker (DFLK) measured coil current exceeds overcurrent limit.

Potential impact

DFLK unable to properly control coil current

Set condition

DFLK measured coil current exceeds expected current limit

Clear condition

Successful DFLK power on self test

Signals to check

These diagnostic fields are associated with DFLKR_a018. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temp DFLKR_a018_ambientTemp DegC
Coil Current DFLKR_a018_coilCurrent A
Coil State DFLKR_a018_coilState
0
INIT
1
ENGAGING
2
ENGAGED
3
DISENGAGING
4
DISENGAGED
5
UNAVAILABLE
6
FAULT
7
UNSECURE
—
Input Voltage DFLKR_a018_inputVoltage V
Instantaneous DFLKR_a018_instantaneous —
Steady State DFLKR_a018_steadyState —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DFLKR_a018.

Browse all DFLKR alert codes