Skip to content

DFLKF_a021 — Self Test Failed

Full alert identifier: DFLKF_a021_selfTestFailed

Alert description

Differential Locker (DFLK) power on self test failed.

Potential impact

DFLK may lose ability to control the coil

Set condition

Coil resistance calculated during self test is out of nominal bounds

Clear condition

Successful DFLK power on self test.

Signals to check

These diagnostic fields are associated with DFLKF_a021. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Coil Current DFLKF_a021_coilCurrent A
Expected Current DFLKF_a021_expectedCurrent A
Input Voltage DFLKF_a021_inputVoltage V
Pcb Temp DFLKF_a021_pcbTemp DegC
Self Test Resistance DFLKF_a021_selfTestResistance Ohm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DFLKF_a021.

Browse all DFLKF alert codes