DFLKF_a018 — Coil Overcurrent
Full alert identifier: DFLKF_a018_coilOvercurrent
Alert description
Differential Locker (DFLK) measured coil current exceeds overcurrent limit.
Potential impact
DFLK unable to properly control coil current
Set condition
DFLK measured coil current exceeds expected current limit
Clear condition
Successful DFLK power on self test
Signals to check
These diagnostic fields are associated with DFLKF_a018. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ambient Temp
DFLKF_
|
DegC |
Coil Current
DFLKF_
|
A |
Coil State
DFLKF_
|
— |
Input Voltage
DFLKF_
|
V |
Instantaneous
DFLKF_
|
— |
Steady State
DFLKF_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DFLKF_a018.