Skip to content

DFLKF_a018 — Coil Overcurrent

Full alert identifier: DFLKF_a018_coilOvercurrent

Alert description

Differential Locker (DFLK) measured coil current exceeds overcurrent limit.

Potential impact

DFLK unable to properly control coil current

Set condition

DFLK measured coil current exceeds expected current limit

Clear condition

Successful DFLK power on self test

Signals to check

These diagnostic fields are associated with DFLKF_a018. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temp DFLKF_a018_ambientTemp DegC
Coil Current DFLKF_a018_coilCurrent A
Coil State DFLKF_a018_coilState
0
INIT
1
ENGAGING
2
ENGAGED
3
DISENGAGING
4
DISENGAGED
5
UNAVAILABLE
6
FAULT
7
UNSECURE
—
Input Voltage DFLKF_a018_inputVoltage V
Instantaneous DFLKF_a018_instantaneous —
Steady State DFLKF_a018_steadyState —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DFLKF_a018.

Browse all DFLKF alert codes