Skip to content

DFLKF_a008 — Di Unit Can MIA

Full alert identifier: DFLKF_a008_diUnitCanMIA

Alert description

Drive Inverter unit (DIx) controller area network (CAN) communication to the differential locker (DFLK) is missing (MIA).

Potential impact

DFLK coil unable to communicate to the DIx.

Set condition

DFLK is not receiving all expected CAN frames from DIx.

Clear condition

DFLK receives all expected CAN frames from DIx.

Signals to check

These diagnostic fields are associated with DFLKF_a008. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dflk Coil Status DFLKF_a008_dflkCoilStatus —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DFLKF_a008.

Browse all DFLKF alert codes