CP_a161 — Bad Pilot Diode Detected CN
Full alert identifier: CP_a161_badPilotDiodeDetectedCN
Alert description
The charge port (CP) electronic control unit (ECU) detects that the control pilot voltage is not within its nominal range indicating a possible issue with the ECU.
Potential impact
AC charging may not be operational on the next attempt. DC fast charging should remain functional.
Set condition
The CP ECU detects that the voltage of the control pilot never goes below -10V.
Clear condition
The CP ECU detects a nominal control pilot voltage or the CP ECU is replaced.
Signals to check
These diagnostic fields are associated with CP_a161. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Pilot High Max
CP_
|
V |
Pilot High Min
CP_
|
V |
Pilot Low Max
CP_
|
V |
Pilot Low Min
CP_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a161.