CP_a135 — Sdp Attempts Failed
Full alert identifier: CP_a135_sdpAttemptsFailed
Alert description
The combined charging system (CCS) charging session is not started due to communication failures during the electric vehicle supply equipment (EVSE) discovery protocol (SDP).
Potential impact
Charging does not start.
Set condition
The CP ECU detects that the SDP failed an unexpected number of times.
Clear condition
The charge port (CP) electronic control unit (ECU) detects that the charge cable was disconnected, or an SDP attempt succeeded.
Signals to check
These diagnostic fields are associated with CP_a135. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Evse Measured Atten
CP_
|
— |
Pilot State
CP_
|
— |
Sdp Err
CP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a135.