CP_a124 — Ivled Fault

Full alert identifier: CP_a124_ivledFault

Alert description

The charge port (CP) electronic control unit (ECU) detects that the IVLED is stuck in an uncontrolled state.

Potential impact

The CP IVLED does not function as expected, either illuminating when not intended or not illuminating when intended.

Set condition

The CP ECU detects that the IVLED is not responding.

Clear condition

The CP ECU detects that the IVLED is responding as expected.

Signals to check

These diagnostic fields are associated with CP_a124. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ivled State CP_a124_ivledState
0
OFF
1
FADING IN
2
ON
3
FADING OUT
—
Ivled Voltage CP_a124_ivledVoltage V