CP_a074 — Failed To Establish V2g Comm
Full alert identifier: CP_a074_failedToEstablishV2gComm
Alert description
The charge port (CP) electronic control unit (ECU) is unable to communicate with the electric vehicle supply equipment (EVSE).
Potential impact
DC fast charging may be unavailable at Combined Charging System (CCS) charge stations.
Set condition
The CP ECU is unable to communicate with the EVSE.
Clear condition
The CP ECU is able to communicate with the EVSE or the charge cable is removed from the charge port.
Signals to check
These diagnostic fields are associated with CP_a074. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Evse Measured Atten
CP_
|
— |
Sdp No Discovery Response
CP_
|
— |
Slac Error Code
CP_
|
— |
Slac State
CP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a074.