Skip to content

CP_a015 — Aps Vov

Full alert identifier: CP_a015_apsVov

Alert description

The charge port (CP) electronic control unit (ECU) detects an over voltage condition on the external low voltage (LV) power supply.

Potential impact

Charging may not start or may be interrupted. If the voltage is too high, the CP ECU may become damaged.

Set condition

The external LV power supply voltage measured by the CP ECU is above 16.5V.

Clear condition

The external LV power supply voltage measured by the CP ECU is below 16.5V.

Signals to check

These diagnostic fields are associated with CP_a015. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Aps Voltage OV CP_a015_apsVoltageOV V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a015.

Browse all CP alert codes