Alert description

High Voltage (HV) compressor does not start multiple times and does not reach the target speed.

Potential impact

Loss of HVAC heating and cooling. Compressor does not operate for the remainder of the power cycle.

Set condition

Compressor is unable to start 5 times during a power cycle.

Clear condition

Vehicle is power cycled.

Signals to check

These diagnostic fields are associated with CMPT_a017. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Voltage CMPT_a017_busVoltage V
Pcba Temp CMPT_a017_pcbaTemp
255
SNA
degC