CMPT_a010 — 1v2 UV

Full alert identifier: CMPT_a010_1v2UV

Alert description

The internal 1V2 supply has an undervoltage condition.

Potential impact

The processor may reboot or stop operating if the condition worsens.

Set condition

The 1V2 supply drops below the lower voltage limit.

Clear condition

The 1V2 supply rises above the clear threshold.

Signals to check

These diagnostic fields are associated with CMPT_a010. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
12 V Voltage CMPT_a010_12vVoltage V
1 V 2 PGOOD CMPT_a010_1v2PGOOD —
1 V 2 Voltage CMPT_a010_1v2Voltage V
3 V 3 PGOOD CMPT_a010_3v3PGOOD —
3 V 3 Voltage CMPT_a010_3v3Voltage V
5 V Voltage CMPT_a010_5vVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CMPT_a010.

Browse all CMPT alert codes