APS_w133 — ETH Switch Error
Full alert identifier: APS_w133_ETHSwitchError
Alert description
Autopilot Processor Secondary (APS) has not initialized the Ethernet switch correctly.
Potential impact
Autopilot communication over Ethernet will be broken.
Set condition
Ethernet switch programming fails or returns error.
Clear condition
Ethernet switch is correctly initialized.
Signals to check
These diagnostic fields are associated with APS_w133. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Eth Switch Failed To Boot
APS_
|
— |
Eth Switch Read Fw Ver Failed
APS_
|
— |
Eth Switch Timedout Update
APS_
|
— |
Failed Init Step
APS_
|
— |
Phy Interrupt Storm
APS_
|
— |
Phy Is Not RMII Mode
APS_
|
— |
Switch Ethernet Inter Link Down
APS_
|
— |
Switch In Reset
APS_
|
— |
Show 1 more field
| Signal | Unit |
|---|---|
Unused
APS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of APS_w133.