ADSP_w067 — Baseamp0 Fault

Full alert identifier: ADSP_w067_baseamp0Fault

Alert description

A electrical fault has been detected in the base amplifier.

Potential impact

Compromised audio performance, signal degradation, or complete loss of audio functionality.

Set condition

A electrical fault has been detected in the base amplifier, possible causes include under-voltage, over-voltage, over-current, over-temperature, clock Phase-Locked Loop issues, or DC offset errors.

Clear condition

The base amplifier electrical fault has been cleared, and normal operation has been restored.

Signals to check

These diagnostic fields are associated with ADSP_w067. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Baseamp 0 Fault ADSP_a067_baseamp0Fault
0
NONE
1
OVER TEMP
2
CLOCK PLL
3
OVER CURRENT
4
OVER VOLTAGE
5
UNDER VOLTAGE
6
DC
7
OTHER
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of ADSP_w067.